SPECIFICATIONS
IR Non-Contact Thermometer
Range /Resolution -20 to 1400°F (-28 to 760°C) / 0.1°
-20 to 30°F (-28 to -1°C) ± 2.0%rdg or ±6°F/3°C
whichever is greater
31°F to 150°F (-0.5 to 65°C) ± 2.0%rdg or ±4.5°F/2.5°C
whichever is greater
151°F to 600°F (66 to 315°C) ± 2.0%rdg or ±4°F/2°C
whichever is greater
600F to 1400°F (316 to 760°C) ± (2.5%rdg + 5°F/2.5°C)
Accuracy
Note: Accuracy is specified for the following ambient temperature
range: 73 to77°F (23 to 25°C)
Emissivity 0.10 to 1.00 adjustable; Note: Automatic emissivity adjustment
above 212°F (100°C)
Distance-to-spot ratio D/S = 13:1 ratio (D = distance; S = spot or target)
Laser pointer Class 2 laser < 1mW power; Wavelength is 630 to 670nm
Spectral response 8 to 14 m (wavelength)
Repeatability ± 0.7% of reading or ± 1.8°F (1°C) whichever is greater
Type K Contact Thermometer
Range / Resolution -58.0 to 1472
o
F (-50.0 to 800
o
C) 0.1
o
<2000, 1°>2000
Accuracy ± (1.5% of rdg + 2ºF/1ºC)
Note: Accuracy is specified for the following ambient temperature
range: 64 to 82ºF (18 to 28ºC)
Type K Bead Wire Probe (supplied)
Range -58.0 to 482
o
F (-50.0 to 250
o
C)
Note: An optional probe that is rated to the full range of the meter
is available from the www.craftsman.com
website.